DeyeБатерияТърговски и индустриални
Deye 100kW–2.5MW C&I ESS Solution (with SUN-80K-CG01-C)
100kW-2.5MW C&I ESS Solution
Цена при запитване
Крайната цена и наличността се потвърждават в писмената ви оферта.
- Категория
- Modular C&I ESS
- Обхват
- 257.23 kWh
Модели и цени
| Модел | Мощност / капацитет | Цена (с вкл. ДДС) |
|---|---|---|
| SUN-MPPT-L01-EU-AM8 | — | При запитване |
| SUN-MPPT-L01-EU-AM8-P | — | При запитване |
| SUN-MPPT-L01-EU-AM10 | — | При запитване |
| SUN-100K-PCS01HP3 | 100 kW | При запитване |
| SUN-125K-PCS01HP3 | 125 kW | При запитване |
| SUN-100K-PCS02HP3 | 100 kW | При запитване |
| SUN-125K-PCS02HP3 | 125 kW | При запитване |
| BOS-B Pro-A3 | 257.23 kWh | При запитване |
| SUN-80K-CG01-C | — | При запитване |
Основни характеристики
- 0 ms Seamless Transfer: Online UPS architecture ensures uninterrupted power supply with true 0 ms transfer time.
- Strong Overload Capability: Supports 2 × peak power output for 15s in off-grid mode, ensuring reliable startup of heavy loads.
- Flexible Expansion: 100/125kW PCS units enable system scalability up to 2.5 MW.
- Large Energy Storage: Up to 257 kWh per battery cluster, supporting up to 16 clusters per PCS.
- Flexible System Design: Supports both DC and AC coupling for new installations, retrofits, and future system expansion.
- Integrated EMS: Supports zero-export, TOU optimization, peak shaving and demand management.
- Flexible Control: Local touchscreen control and remote monitoring via Deye Cloud.
- Advanced Battery Safety: Combines LiFePO₄ battery technology with integrated module-level aerosol fire suppression for enhanced battery safety.
Технически спецификации
| Max. PV access power(kW) | 200 / 250 / 250 |
|---|---|
| Max. PV Input Power(kW) | 160 / 200 / 200 |
| Max. PV Input Voltage (V) | 800 |
| Start-up Voltage (V) | 200 |
| MPPT Voltage Range (V) | 180-750 |
| Full Load MPPT Voltage Range(V) | 450-750 |
| Rated PV Input Voltage (V) | 600 |
| Max. Operating PV Input Current (A) | 40+40+40+40+40+40+40+40 / 48+48+48+48+48+48+48+48 / 40+40+40+40+40+40+40+40+40+40 |
| Max. Input Short-Circuit Current (A) | 60+60+60+60+60+60+60+60 / 72+72+72+72+72+72+72+72 / 60+60+60+60+60+60+60+60+60+60 |
| No. of MPP Trackers | 8 / 8 / 10 |
| Max. Efficiency | >99% |
|---|---|
| MPPT Efficiency | >99.9% |
| DC input reverse protection | YES |
|---|---|
| DC ARC protection | Optional |
| Anti-PID(Potential Induced Degradation) | Optional |
| DC Switch | YES |
| Surge Protection Level | TYPE II |
| Ingress Protection(IP) Rating | IP65 |
|---|---|
| Over Voltage Category | OVC II |
| Cabinet Size[W×H×D] (mm) | 543x198x700 / 543x198x700 / 543x198x720 |
| Weight (kg) | 41.75 / 41.75 / 50.6 |
| Type Of Cooling | Intelligent air cooling |
| Safety EMC/Standard | IEC/EN 62109-1 |
| DC Output VoltageRange ( V ) | 630-1000 |
|---|---|
| Max. DCOutput Current ( A ) | 200 / 250 / 250 |
| Battery Type | Lithium-ion |
|---|---|
| Battery Voltage Range (V) | 630-1000 |
| Max. Charging Current (A) | 175 / 200 / 175 / 200 |
| Max. Discharging Current (A) | 175 / 200 / 175 / 200 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS |
| Number of Battery Input | 1 |
| DC Input Voltage Range(V) | 630-1000 |
|---|---|
| Max. DC Input Current(A) | 200 / 200 / 250 / 250 |
| Rated AC Input/Output Active Power (kW) | 100 / 125 / 100 / 125 |
|---|---|
| Max. AC Input/Output Apparent Power (kVA) | 110 / 125 / 110 / 125 |
| Rated AC Input/Output Current (A) | 151.6/145 / 189.4/181.2 / 151.6/145 / 189.4/181.2 |
| Max. AC Input/Output Current (A) | 166.7/159.5 / 189.4/181.2 / 166.7/159.5 / 189.4/181.2 |
| Rated Input/Output Voltage/Range(V) | 220/380, 230/400 0.85Un-1.1Un |
| Grid Connection Form | 3L+N+PE |
| Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
| Power Factor Adjustment Range | -1~1 |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5% In |
| Max. Efficiency | 98.5% |
|---|---|
| Euro Efficiency | 97.8% |
| Integrated | AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, Anti - islanding Protection, Insulation Impedance Detection,Residual Current Detection |
|---|---|
| Surge Protection Level | TYPE II(DC),TYPE II(AC) |
| LCD/LED display | LCD |
|---|---|
| Communication Interface | WIFI, RS485, CAN, Meter |
| Operating Temperature Range(℃) | -40℃to -60℃,>45℃ Derating |
|---|---|
| Permissible Ambient Humidity | 0-95% |
| Permissible Altitude | 4000m |
| Noise | <75dB |
| Ingress Protection(IP) Rating | IP 65(PCS Module) |
| Cabinet Size[W×H×D] (mm) | 543x310x775(Excluding connectors and brackets) |
| Weight (kg) | 81.86 |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Type of Cooling | Intelligent Air Cooling |
| Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99,VDE-AR-N 4105 |
| Safety/EMC Standard | IEC/EN 62477-1 |
| Battery Module Energy ( kWh ) | 16.08 |
|---|---|
| Battery Module Nominal Voltage ( V ) | 51.2 |
| Battery Module Capacity ( Ah ) | 314 |
| Module Weight Approximate ( kg ) | 126 |
| Battery Module Qty In Series ( Optional ) | 5~16 |
| Matching Mode | PCS:14-16 units for PCS on-grid applications, 15-16 units for PCS off-grid applications |
| Matching Mode | PCS + MPPT: 16units (on/off-grid) for MPPT Open-Circuit Voltage ≤800V;15 units (on/off-grid) for MPPT Open-Circuit Voltage ≤750V; 14units (on-grid) for MPPT Open-Circuit Voltage ≤ 700V |
| Max.System Nominal Voltage ( V ) | 819.2 |
| Max.System Energy ( kWh ) | 257.23 |
| Max.System Usable Energy ( kWh ) | 231.51 |
| Max.Charge/Discharge Current ( A) | 180 |
| Operating Temperature ( ℃ ) | Charge :0 ~ 55 Discharge :-20 ~ 55 |
|---|---|
| Storage Temperature ( ℃ ) | 0 ~ 35 |
| Thermal Management | Smart fan cooling |
| LCD Display | SOC / Fault Code |
| Status Indicator | Yellow : Battery High Voltage Power On Red : Battery System Alarm |
| Communication Port | TCP / RS485 / CAN |
| Communication With BMS | CAN |
| Humidity | 5% ~ 85% |
| Altitude | ≤3000m |
| IP Rating of Enclosure | IP20 |
| Noise ( dB ) | TBD |
| System Dimension ( W × H × D, mm ) | 2150 × 1305 × 800 |
| System Weight Approximate ( kg ) | 2240 |
| Installation Location | Rack Mounted |
| Recommend Depth of Discharge | 90% |
| Cycle Life | 25±2°C, 0.5C / 0.5C, EOL70%≥6000 |
| Warranty Period | 10 years |
| Certification | CE / IEC62619 / IEC62040 / UN38.3 |
| Input Voltage Range | 260Vac ~ 530Vac, 3L+PE |
|---|---|
| Max Input Current(A) | 160 |
| Frequency Range | 45Hz ~ 65Hz |
| Power Factor | ≥0.99 |
| Efficiency | Full load > 96%, peak > 97% |
| THD | <5% |
| Output Power(kW) | 80 |
|---|---|
| Voltage Range | 50Vdc ~ 1000Vdc |
| Constant Power Output Voltage Range | 300Vdc ~ 1000Vdc |
| Output Current(A) | 0 ~ 266 |
| Output Current Limiting | 0.3 ~ 266A continuously adjustable |
| Current Sharing | Imbalance < ±5% |
| Voltage Regulation Accuracy | < ±0.5% |
| Current Regulation Accuracy | ≤ ±1% (within 20%~100% rated output load) |
| Operating Temperature | -40°C ~ +75°C, derating required above +55°C |
|---|---|
| Relative Humidity | ≤95% RH, non-condensing |
| Cooling Method | Forced air cooling |
| Grid Connection Form | 3L |
| Altitude | ≤2000m, derating required above 2000m |
| Dimensions[W×H×D] (mm) | 543×127×740 (excluding handles and terminal protrusions) |
|---|---|
| Weight (kg) | 42.2 |
| Battery Type | RS485 |
|---|
Спецификации, публикувани от Deye. Проверете най-новата техническа спецификация преди поръчка. Продуктова страница на уебсайта на производителя(отваря се в нов раздел)